PUMC
Linked In Facebook Twitter YouTube PUMC Blog Subscribe (203) 743-6741
PUMC Home : Product Divisions : Preferred Instruments : Category

Flame Safeguard Components

The synthesis of GN Electronics and Preferred Instruments brings a new level of seamless integration between combustion control and flame safeguard technology for many process applications. Whether your goal is to increase automation, reduce fuel costs, or remotely monitor your control processes, our wide range of products and engineering expertise ensures our ability to create the most reliable and cost effective solutions for all of your needs. These products include a variety of control components designed to monitor and provide flame safeguard technology for burners used on NFPA 85 and NFPA 86 fired equipment applications. Preferred Utilities' industrial factory is located in Danbury, CT (Connecticut).

Key Features

  • Interfaces with Preferred, Fireye, Honeywell, and PCI Products
  • No Scheduled Replacement Parts
  • No Re-Wiring Required

PRODUCTS
5004-04FS Multifunctional Tester
Multifunctional Flame Simulator, Model 5004-04-FS - Tool for testing and demonstrating the 5004-890 and the 5004-795 control units. It can also be used to test and demonstrate various UV sensors that can be connected to the tester via the external sensor connector on the left side of the tester.

Quanta Flame 5004 Panel Display
Optional Display Available for the Quanta Flame 5004 Series Flame Safeguard Controllers

Quanta Flame 5004-01 UV Scanner
Ultraviolet (UV) Sensor for Monitoring Gas or Oil Flames - Scanners are recommended for detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil.

Quanta Flame 5004-795 Flame Safeguard Controller
Model 795 Flame Safeguard Controller, Direct Replacement for Honeywell R4795 Controls - Sequences the burner through Purge, Ignition, Pilot Trial for Ignition, Main Trial for Ignition, and Run modes. It monitors the burner flame and running interlocks to safely shut down the burner in the event of an unsafe operating condition.

Quanta Flame 5004-890 Flame Safeguard Controller
Model 890 Flame Safeguard Controller - Sequences the burner through Ignition, Pilot Trial for Ignition, and Main Flame Trial for Ignition. The 5004-890 controller is a direct replacement for most Honeywell RA890 controls.

Quanta Flame 5004-M Flame Safeguard Controller
Single Burner Process Flame Safeguard Controller - Designed for single burner process heat applications such as ovens, furnaces, kilns, and dryers. The controller accepts one or two scanners per burner.

Quanta Flame 5004-M-110 Flame Safeguard Controller
The Quanta-Flame 5004-M-110 controller is a state-of-the-art microcomputer based Burner Management System designed for a single burner boiler or process heat application. An LCD display provides real-time diagnostic and status messages for the operator. Unlike other flame safeguard controllers that require a variety of modules to make a complete system (programmers, flame amplifiers, displays, etc.) the Preferred Quanta-Flame 5004-M-110 has just one processor with a built-in universal amplifier that accepts UV, IR and Flame Rod inputs. Service technicians can carry this one processor on their trucks and be equipped to replace a large number of existing flame safeguard controller combinations.

Quanta Flame 5004-M-78 Replacemement Flame Safeguard Controller
Direct Replacement for Cleaver Brooks CB780 and Honeywell RM7800 Series Flame Safeguard Controllers - Has just one processor with a built-in amplifier that accepts UV, IR, and self-checking UV scanner inputs, as well as flame rod inputs. It can also accepts two scanners simultaneously on separate inputs. In addition, Purge times and Main Trial For Ignition (MTFI) times are field-selectable.

Quanta Flame 5004-M-85 Flame Safeguard Controller
Model 5004-M-85, Flame Safeguard Controller - Has just one processor with a built-in amplifier that accepts UV, IR, and self-checking UV scanner inputs, as well as flame rod inputs. It can also accepts two scanners simultaneously on separate inputs. In addition, Purge times and Main Trial For Ignition (MTFI) times are field-selectable.

Quanta Flame Series 5002-01 Self Checking UV Scanner
Ultraviolet Self Checking Flame Scanners - Ideal for natural gas, landfill gas, refinery gas, and light oil fired burners. It interfaces with Preferred, Honeywell, Fireye, Siemens, Eclipse, and PCI flame safeguard microprocessors.

Quanta Flame Series 5002-01NC UV Scanner
Ultraviolet Flame Scanner - Applicable to gas and light oil fired burners for boilers and process heat applications. The standard model interfaces with Preferred, Fireye, and Honeywell flame safeguard controllers.

Quanta Max Multiple Burner Flame Input Module
Model 5003-01T, Multiple Burner Flame Input Module - Ideal for ovens, kilns, cabin heaters, and other furnaces that have multiple burners but just one fuel header safety shutoff valve. This system is not appropriate for boilers because NFPA 85 requires individual burner safety shutoff valves for multiple burner boilers.

Quanta-M Universal Tester Kit
Flame Safeguard Controller Universal Tester Kit - Used with most brands of burner controls by wiring it into the versatile connector of the tester.